Coaxial Cable Specifications

image_pdfimage_print

Center Conductor:

  • 18 AWG Solid Bare Copper
  • Nominal Diameter: 0.0403”

Shield:

  • Foil: Aluminum/Poly Tape
  • Braid: 34 AWG Aluminum
  • Nominal 60% Coverage
  • Nominal Diameter 0.2012”

Dielectric:

  • Foam Polyethylene
  • Diameter over Dielectric: 0.180” Nom.

Jacket:

  • PVC (Indoor) or PE (Outdoor)
  • Diameter over Jacket: 0.272” +/- 0.006”
  • Nominal Jacket Thickness: 0.030”
  • Minimum Spot: 0.024”

Mechanical Properties

Minimum Bend Radius:

  • Loaded: 5.4 Inched
  • Unloaded: 2.7 Inches

Cable Temp. Rating:

  • Temp:75C
  • UL 444 Cold Bend to -40C (PVC) -55C (PE)
  • Cold Impact @ -15C (PVC) -22C (PE)
  • CM or CMX Fire Rated

Electrical Properties

Sparker Test:

  • 4000 VAC

Velocity of Propagation:

  • 82.0% Nom.

Dielectric Strength:

  • Conductor to Shield: 3000 VDC

DCR Conductor:

  • 6.4 Ohms/1000 FT. Max

Capacitance:

  • 16.0 PF./FT. Nom.

DCR Shield:

  • 10.5 Ohms/1000 FT. Max

Impedance:

  • 75.0 +/- 3.0 Ohms

SRL:

  • 15dB 100 MHz to 3000 MHz minimum
  • 100% Swept Tested

Attenuation

C:\Users\jloera\Desktop\dBchart.png