Coaxial Cable Specifications
Center Conductor:
- 18 AWG Solid Bare Copper
- Nominal Diameter: 0.0403”
Shield:
- Foil: Aluminum/Poly Tape
- Braid: 34 AWG Aluminum
- Nominal 60% Coverage
- Nominal Diameter 0.2012”
Dielectric:
- Foam Polyethylene
- Diameter over Dielectric: 0.180” Nom.
Jacket:
- PVC (Indoor) or PE (Outdoor)
- Diameter over Jacket: 0.272” +/- 0.006”
- Nominal Jacket Thickness: 0.030”
- Minimum Spot: 0.024”
Mechanical Properties
Minimum Bend Radius:
- Loaded: 5.4 Inched
- Unloaded: 2.7 Inches
Cable Temp. Rating:
- Temp:75C
- UL 444 Cold Bend to -40C (PVC) -55C (PE)
- Cold Impact @ -15C (PVC) -22C (PE)
- CM or CMX Fire Rated
Electrical Properties
Sparker Test:
- 4000 VAC
Velocity of Propagation:
- 82.0% Nom.
Dielectric Strength:
- Conductor to Shield: 3000 VDC
DCR Conductor:
- 6.4 Ohms/1000 FT. Max
Capacitance:
- 16.0 PF./FT. Nom.
DCR Shield:
- 10.5 Ohms/1000 FT. Max
Impedance:
- 75.0 +/- 3.0 Ohms
SRL:
- 15dB 100 MHz to 3000 MHz minimum
- 100% Swept Tested
Attenuation